Cascadable interface device for recording measurement data
- For connection to the USB port of a computer, another CASSY module or the CASSY display (524 020USB
- Sensor-CASSY (524 010), Sensor-CASSY 2 and Power-CASSY (524 011USB) can be mixed in cascades
- 3-fold electrical isolation (4-mm inputs A and B, relay R)
- Measurement possible simultaneously at 4-mm inputs and sensor box connector sites (4 channels)
- Cascading of up to 8 CASSY modules possible (to expand the inputs and outputs)
- Up to 8 analog inputs can be provided by adding Sensor-CASSY sensor boxes
- Automatic sensor box detection (plug and play) by CASSY Lab 2 (524 220)
- Microprocessor-controlled with CASSY operating system (easily updatable via software for function enhancements)
- For use as a bench-top, console or demonstration unit (also in CPS/TPS panel frames)
- Voltage supply 12 V AC/DC via cannon plug or adjacent CASSY module
- Developer Information, LabVIEW and MATLAB driver available through our internet homepage
- 5 analog inputs
2 analog voltage inputs A and B on 4-mm safety sockets (electrically isolated)
Resolution: 12 bits
Measuring ranges: ±0.1/±0.3/±1/±3/±10/±30/±100/±250 V
Measurement error: ±1% plus 0.5% of range end value
Input resistance: 1 MΩ
Scanning rate: up to 1 MHz per input
Amount of measured values: nearly unlimited (dependent on PC) up to 10,000 values/s, at higher measuring rate max. 200,000 values
Pre-trigger: up to 50,000 values per input
1 analog current input A on 4-mm safety sockets (alternatively to voltage input A)
Measuring ranges: ±0.03/±0.1/±0.3/±1/±3 A
Measurement error: voltage error plus 1%
Input resistance: < 0.5 Ω
Scanning rate: up to 1 MHz per input
See voltage inputs for further data
2 analog inputs at sensor box connector sites A and B
(All CASSY sensor boxes and sensors can be connected)
Measuring ranges: ±0.003/±0.01/±0.03/±0.1/±0.3/±1 V
Input resistance: 10 kΩ
Scanning rate: up to 500 kHz per input
See voltage inputs for further data
The technical data will change depending on a connected sensor box. In this case CASSY Lab 2 automatically detects the possible measurement quantities and ranges when a sensor box is attached. - 4 timer inputs with 32-bit counters at sensor box sites A and B (e.g. for GM box, timer box or Timer S)
Counting frequency: max. 1 MHz
Time resolution: 20 ns - 5 LED status indicators for analog inputs and USB-port
Colours: red and green, according to status
Light intensity: adjustable - 1 change-over relay (switching indication via LED)
Range: max. 250 V/2 A - 1 analog output (LED switching state indicator, e.g. for holding magnet or supplying experiment)
Variable voltage range: max. 16 V/200 mA (load ≥ 80Ω) - 12 digital inputs (TTL) on sensor box sites A and B (at present only used for automatic sensor box detection)
- 6 digital outputs (TTL) on sensor box sites A and B (at present only used for automatic switching of a sensor box measuring range)
- 1 USB port for connection to a computer
- 1 CASSY bus for connecting additional CASSY modules
- Dimensions (WxHxD): 115 mm x 295 mm x 45 mm
- Weight: 1.0 kg
- Sensor-CASSY 2
- USB cable
- Plug-in supply unit 230V, 12V/1.6A
MSI | CASSY Lab 2 (en, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (fr, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (es, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (pt, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (it, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (nl, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (ru, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (zh, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
Manual | CASSY Lab 2 Manual (en) |
Manual | CASSY Lab 2 Manual (fr) |
Manual | CASSY Lab 2 Manual (es) |
Web Link | CASSY Lab 2 Web Help (en) |
Web Link | CASSY Lab 2 Web Help (fr) |
Web Link | CASSY Lab 2 Web Help (es) |
ZIP | CASSY SDK for own software development (Windows/Linux) |
ZIP | LabVIEW driver for LabVIEW 2017 or higher (Windows) |
ZIP | MATLAB driver with examples (Windows) |
Web Link | CASSY App (iOS) App Store |
Web Link | CASSY App (Android) Google Play |
Web Link | CASSY App (Windows 10) Microsoft Store |