Sensor-CASSY, 3 HU
524013K
Interface device for recording measurement data
- For connection to the USB-port of a computer
- 3-fold electrical isolation (4-mm-inputs A and B, relay R)
- Measurement possible parallel at 4-mm-inputs and sensor box connector sites (4 channels)
- Up to 8 analog inputs per Sensor-CASSY retrofittable using sensor boxes
- Automatic sensor box detection (plug and play) by CASSY Lab 2 (524 220)
- Microprocessor-controlled with CASSY operating system (easily updatable via software for function enhancements)
- Developer Information and LabVIEWTM driver available through our internet homepage
- Assembled in a 3 HU module to be integrated into a power supply channel. The USB socket is located at the front side.
Technical data
- 5 Analog inputs
2 Analog voltage inputs A and B on 4-mm safety sockets (electrically isolated)
Resolution: 12 bits
Measuring ranges: ± 0.1/0.3/1/3/10/30/100/250 V
Measurement error: ± 1 % plus 0.5 % of range end value
Input resistance: 1 MΩ
Scanning rate: up to 1 MHz per input
Amount of measured values: nearly unlimited (dependent on PC) up to 10,000 values/s, at higher measuring rate max. 200,000 values
Pre trigger: up to 50,000 values per input
1 Analog current input A on 4-mm safety sockets (alternatively to voltage input A)
Measuring ranges: ± 0.03/0.1/0.3/1/3 A
Measurement error: voltage error plus 1 %
Input resistance: < 0.5 Ω
Scanning rate: up to 1 MHz per input
See voltage inputs for further data
2 Analog inputs at sensor box connector sites A and B
(All CASSY sensor boxes and sensors can be connected)
Measuring ranges: ± 0.003/0.01/0.03/0.1/0.3/1 V
Input resistance: 10 kΩ
Scanning rate: up to 500 kHz per input
See voltage inputs for further data
The technical data will change depending on a connected sensor box. In this case CASSY Lab 2 automatically detects the possible measurement quantities and ranges when a sensor box is attached. - 4 Timer inputs with 32-bit counters at sensor box sites A and B (e.g. for BMW box, GM box or timer box)
Counting frequency: max. 1 MHz
Time resolution: 20 ns - 1 Changeover relay (switching indication via LED)
Range: max. 250 V / 2 A - 1 Analog output (LED switching state indicator, e.g. for holding magnet or supplying experiment)
Variable voltage range: max. 16 V / 200 mA
(load ≥ 80 Ω) - 12 Digital inputs (TTL) on sensor box sites A and B (at present only used for automatic sensor box detection)
- 6 Digital outputs (TTL) on sensor box sites A and B (at present only used for automatic switching of a sensor box measuring range)
- 1 USB-port for connection to a computer
Scope of supply:
1 Sensor-CASSY 2
1 USB cable
Width: 63 PU
MSI | CASSY Lab 2 (en, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (fr, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (es, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (pt, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (it, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (nl, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (ru, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
MSI | CASSY Lab 2 (zh, V2.27) Free demo version, full version requires a licence code of CASSY Lab 2 |
Manual | CASSY Lab 2 Manual (en) |
Manual | CASSY Lab 2 Manual (fr) |
Manual | CASSY Lab 2 Manual (es) |
Web Link | CASSY Lab 2 Web Help (en) |
Web Link | CASSY Lab 2 Web Help (fr) |
Web Link | CASSY Lab 2 Web Help (es) |
ZIP | CASSY SDK for own software development (Windows/Linux) |
ZIP | LabVIEW driver for LabVIEW 2017 or higher (Windows) |
ZIP | MATLAB driver with examples (Windows) |
Web Link | CASSY App (iOS) App Store |
Web Link | CASSY App (Android) Google Play |
Web Link | CASSY App (Windows 10) Microsoft Store |