Position pick-up with rotating angular disc for application in servo systems. With input summing point for forward feeding of disturbance variables or for setpoint variable change and with connectable rate-of-change limiter with rise times of 1 V/s up to 1000 V/s.
- Signal voltage range: -10 V...+10 V
- Rotating angle:
Mechanical 360° without limit stop
Electrical 340° ±5° - Fine setting of zero-point and scale factor
- Coarse setting with rotary switch
- Fine setting with potentiometer
- Supply voltage: ±15 V DC