This device makes possible the synchronous demodulation of SSB and DSB signals with and without carrier, and the recovery of the carrier from the pilot tone. The effects of phase faults on synchronous demodulation can also be investigated.
- Supply voltage: ± 15 V DC
- Current consumption: 80 mA
- Auxiliary carrier: 20 kHz square wave
- Pilot tone: 160 kHz
- Channel filter for upper side band: 20 kHz...30 kHz
- Frequency cut-off of the output low-pass filter: 3.4 kHz