Squirrel cage rotor, 400/690, 0.3
The tests are carried out with industrially manufactured machines. All test machines have a special base for connection to the Machine Test System 0.3. With the Machine Test CASSY all measured values of the AC machines are recorded. The measured values can be shown directly on the built-in display as a single value, table of a measurement series or diagram. The measurements can be made without additional software, and the measured data can be stored locally on the unit. The Machine Test CASSY is used to record the characteristic curves of the test machines. The power supply for the test machines is partly taken directly from the public supply network.
Objectives
- Protective measures and electrical safety
- Construction and commissioning of electrical machines
- Use of starting circuits
- Efficiency of the machine
- Assessment of characteristic curves of electrical machines
Asynchronous machines as squirrel cage rotors are widely used. These are particularly low-maintenance motors. With the supply by frequency converters, these are increasingly replacing DC machines. Squirrel cage asynchronous machines are used as motors and rarely as generators. The asynchronous motor in this configuration has the suffix 400 / 690 V, which corresponds to the rated voltage specification of the motor. Only with this voltage does the motor have to be operated in a 230 V / 400 V in delta and therefore starting can also take place in star delta.
Highlights:
- To protect against overheating, the stator windings of the test machines are equipped with temperature detectors.
- In case of overheating, the machine testing system switches off the load of the test machine, thus maintaining the air cooling. This prevents damage to the testing machines.
- The test machines have a didactic terminal board with the winding diagram printed on it.
- The ends of all the windings are led out at the terminal board at safety sockets (4 mm).
- Computer-aided measured value acquisition provides meaningful measurement results.
- The arrangement of the 4 mm safety sockets complies with the standards for industrial motors.
All functions of the Machine Test CASSY 0.3 can be operated quickly and directly via the display, the rotary wheel and the buttons on the unit. All settings and measurement results can be saved on the unit and quickly called up again later or simply downloaded.
In addition, the Machine Test CASSY 0.3 is fully controllable in real time via RJ45 Ethernet, W-LAN and USB-C interfaces.
These interfaces can be used by the following software:
- CASSY Lab 2 for drives and energy systems,
- MATLAB® and LabVIEW ™
- Lab Docs Editor Advanced
The following integrated servers are available in the Machine Test CASSY 0.3 for the local media connection of at least four end devices simultaneously.
For more details, see product data 7731900 or 7731901 Machine Test CASSY 0.3
The individual equipment is equally suitable for student experiments in the laboratory with low voltage (230 / 400 V three-phase current) and - with a mobile trainer - for teacher demonstration in the classroom. The experiments are carried out according to the manual.
The target group is made up of commercial apprentices and students of electrical machine construction. The course offers experiments at an intermediate level and also allows for the necessary insight into machine behaviour for scientific interpretation at undergraduate level. The media connection makes the experiments suitable for demonstration in the classroom or a lecture hall.
In the following configurations there are further extended experiments with asynchronous machines:
- E2.2.4.2 Squirrel cage rotor, 230/400
- E2.2.4.3 Squirrel cage rotor, 230/400 IE3
- E2.2.4.4 Slip-ring rotor
- E2.2.4.5 Squirrel cage rotor D
- E2.2.4.6 Multi-function machine
- E2.5.4.1 Direct start and star-delta start of an asynchronous motor under load
- E.2.5.4.2 Direct starting or starting with a soft starter of an asynchronous motor under load
Topics
- Design and function
- Characteristics on motor operation
- Star-delta starting
- Braking
- Efficiency
- Open-circuit test
- Short-circuit test
Main components:
1 | 773 212 | Squirrel cage motor 400/690, 0.3 |
1 | 732 13 8 | Motor protection switch, 0.6-1 |
1 | 731 44 | Motor protection switch, 0.4-0.6 |
1 | 745 563 | Power circuit breaker |
1 | 773 1900 | Machine Test CASSY, 0.3 |
1 | 524 222 | CASSY Lab 2 for Drives and Power Systems |
1 | 773 1991 | Electrical dynamometer, 0.3 |
1 | 773 108 8 | Coupling / shaft end guard 0.3, transparent |
1 | 315 39 4 | Weight, 1 kg |
1 | 773 110 | Machine base bench, 90 cm |
1 | 773 115 | Machine base bench, 120 cm |
1 | 731 06 4 | Coupling, 0.3 |
1 | 731 49 8 | Reversing switch |
1 | 731 47 8 | Star-delta switch |
1 | 731 48 8 | Star-delta reversing switch |
1 | 731 50 4 | Star-delta starter |
1 | 731 51 8 | * Soft starter, 0.3 /1.0 |
1 | 732 41 8 | * Capacitive load 0.3 |
1 | 773 1391 | * Squirrel cage fault simulator |
1 | 727 293 | * Digital insulation tester |
1 | 739 836 | * Milliohm meter |
1 | 775 200DE 4 | LIT-print: Asynchronous machines 0.3, German |
1 | 775 200EN 4 | * LIT-print: Induction Machines 0.3 |
1 | 726 75 8 | Three-phase terminal unit with RCD |
1 | 726 09 4 | Panel frame T130, two-level |
2 | 500 59 8 | Safety bridging plugs, black, set of 10 |
1 | 500 591 4 | Safety bridging plugs, yellow/green, set of 10 |
1 | 500 855 4 | Safety experiment cables, 32 A, set of 34 |
1 | 500 856 4 | Safety experiment cables, 32 A, yellow/green, set of 5 |
1 | 773 181 4 | Assembly set el. machine base 0.3 short |
1 | 773 182 4 | Assembly set el. machine base 0.3 long |
Articles marked with * are not essential, we do however recommend them to carry out the experiment.