Trainer Package 6 x LOGO 8
E6.6.2.11
Contains six setups for programming a small controller on LOGO! 8 from Siemens.
Educational objectives
- Operating a small controller.
- Creating programs.
- Learning the essential logic and control functions of small controllers.
- Testing the programs.
- Configuring network connections.
The teaching packet consists of:
- LOGO8! 12/24 RCE
- EXPANSION MODULE LOGO! DM8 12/24R
- LOGO! Soft Comfort V8
- Base plate small controller.
Description of the base plate small controller
- 14 digital inputs and 10 transistor outputs are connected with the base plate via 4 mm safety connectors.
- Inputs can be wired with the notch and push function with the incorporated switches.
- There is also the option of firmly establishing the connectors for 24 V DC.
- Analogue signals can be processed over two analogue inputs and two analogue outputs. The controller has an ethernet interface that is constructed as RJ 45.
- The control voltage amounts to 24 V DC.
Method
- Student experiments are carried out following the tasks set in the experiment description.
Students completing vocational training in electrical engineering for a trade or industry are the target group addressed. The course conveys knowledge on an intermediate level.
Previous knowledge
- Basics of contactor switches
- Programming small controllers
- Instruction in the dangers of electrical technology
The learning system can be supplemented with the following equipment:
- E6.5.2.11 Contactor controls with modules, 24 V
- E6.5.2.21 Contactor control with experiment plates, 24 V
- E6.5.2.5 Controlling with limit and proximity switches
- E6.7.1.1 ASIMA for small controllers.
Topics
- Programming a small controller
- Logic connections
- Timer and clock timer functions
- RS components
- Measure counting and frequencies
- Analogue value processing
- Desired value and controlling
- Webserver
- App for LOGO!8
1 | 773 045 8 | LOGO! 8 12/24 TP 6 x |
6 | 773 010 8 | Power Supply DC 24 V / 6.5 A |
6 | 562 793 4 | Plug-in power supply for torsion pendulum |
6 | 689 3000 4 | RJ45 crossover Cable 2m |
6 | 773 055 | * HMI Touch Panel Basic |
6 | 726 10 4 | * Panel frame T150, two-level |
6 | 500 59 8 | Safety bridging plugs, black, set of 10 |
6 | 500 591 4 | * Safety bridging plugs, yellow/green, set of 10 |
6 | 773 050 | * ASIMA Plant Simulator II |
1 | 700 00CBT | * DVD: COM3LAB Software |
1 | A selection of 12 masks can be found in E6.7.1.1. | |
6 | 773 04901 4 | Mask M1 Logic basic functions |
6 | 773 04902 4 | Mask M2 Digital function modules |
6 | 773 04903 4 | Mask M3 Motor ON/OFF |
6 | 773 04904 8 | Mask M4 Reversing contactor |
6 | 773 04905 4 | Mask M5 Star-delta connection |
6 | 773 04906 8 | Mask M6 Reversing star-delta connection |
6 | 773 04907 4 | Mask M7 Pendulum table control |
6 | 773 04908 4 | Mask M8 Dahlaner circuit |
6 | 773 04909 8 | Mask M9 Motor with 2 windings |
6 | 773 04911 8 | Mask M11 Conveyor belt system |
6 | 773 04912 4 | Mask M12 Reactive-current compensation |
6 | 773 04913 4 | Mask M13 Heating control |
1 | 8-2600001-000-10-0 4 | Transparent folder, 410 mm x 320 mm x 10 mm |
1 | 775 790DE 4 | LIT-print: ASIMA, German |
1 | 775 790EN 4 | LIT-print: ASIMA |
144 | 500 624 4 | * Safety experiment cable, 50 cm, black |
6 | 500 621 4 | * Safety experiment cable, 50 cm, red |
6 | 500 622 4 | * Safety experiment cable, 50 cm, blue |
1 | additionally required: 1 PC with Windows 7 / 8.1 / 10 (x86 or x64) |
Articles marked with * are not essential, we do however recommend them to carry out the experiment.